DVP12SA211T,PLC CPU
- Size Guide
Size Guide
DRESSEST-SHIRTBOTTOMSDRESSESSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
T-SHIRTSize Chest Waist Hips 2XS 32 26 32 XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 All measurements are in INCHES
and may vary a half inch in either direction.
BOTTOMSSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- and can be installed easily. Users do not have to install any batteries in DVP-SE series PLCs. The PLC programs and the latched data are stored in the high-speed flash memories.
- D/A conversion and temperature measurement). 2 points of 100 kHz and 2 points of 10 kHz high-speed pulse output satisfy all kinds of applications. Small in size
- Encoder
- including digital I/O (max. 480 I/O points) and analog modules (for A/D
- No of Inputs 14 Digits Power 24 V DC PLC Brand Delta Minimum Order Quantity 1 Piece
- Pressure Sensor
- Pressure transmitter
- various instructions and with 16k steps program memory Connect to all DVP Slim type series extension modules and high-speed extension modules
Related Products
DVP32ES200R
Delta Products Programmable Logic Controllers, DVP-ES2 Series
Brand: Delta
Model: DVP-32ES200R
Supply Voltage: 24VDC
Digital Inputs: 16
Digital Outputs: 16
Output Type: Relay type
4 in stock
Specifications
Attribute | Value |
For Use With | FX2N Series |
Manufacturer Series | FX2N |
Number of Inputs | 40 (Digital) |
Output Type | Relay |
Input Type | Digital |
Voltage Category | 100 → 240 V ac |
Number of Outputs | 40 (Relay) |
Communication Port Type | RS232, RS422, RS485 |
Program Capacity | 8000 Steps |
Programming Language Used | Ladder Logic |
Mounting Type | DIN Rail |
Programming Interface | Computer |
Length | 90mm |
Dimensions | 90 x 285 x 87 mm |
Battery Backup | Yes |
Depth | 87mm |
Number of Communication Ports | 1 |
Width | 285mm |
Minimum Operating Temperature | 0°C |
Maximum Operating Temperature | 55°C |
Output Current | 2 A |
- Made in JAPAN
1 in stock
- Manufacturer : Mitsubishi Electric
- Product No. : FX3U-32MR/ES-A
- Product type : Main Units with 32 I/O
- Max.Number Input/Output : 32
- No. of Inputs : 16
- No. of Outputs : 16
- Type of Output : Relay
- Power Supply : 100-240V AC
- Power Consumption : 35W
- Made in Japan
1 in stock
SERIES | MELSEC IQ-F SERIES |
---|---|
TYPE | DC INPUT (SINK/SOURCE) |
POWER SUPPLY (V) | 24 |
CURRENT TYPE | DC |
OCCUPIED I/O POINTS ON PLC | 16 |
INTEGRATED DIGITAL INPUTS | 16 |
Made In JAPAN
1 in stock
- Manufacturer : Mitsubishi Electric
- Product No. : FX2N-16EX-ES/UL
- Product type : Input Module Extension Block
- Integrated Inputs : 16 (24 VDC)
- Integrated Inputs / Outputs : 16
- ON Voltage (Max.) : Relay version: < 240 VAC, < 30 VDC; Transistor version: 5 – 30 VDC; Triac version: 85 – 242 VAC
- Stocked Item : S
- 5VDC Current Consumption (mA) : 4
2 in stock
odel | ATO-DVP-ES2 | ||||||
Builit-in I/O | 16 / 20 / 24 / 32 / 40 / 60 I/O points | ||||||
Power Supply | 100 ~ 240V AC (-15% ~ +10%), 50/60Hz ±5% | ||||||
Connector | European standard removable terminal block (Pin pitch: 5mm) | ||||||
Operation | ATO-DVP-ES2 PLC starts to run when the power rises to 95~100V AC and stops when the power drops to 70V AC. If the power is suddenly cut off, the PLC will continue running for 10ms. |
||||||
Power Supply Fuse | 2A / 250V AC | ||||||
Power Consumption | 30VA | ||||||
DC 24V Current Output *1 | 500mA | ||||||
Power Supply Protection | DC 24V output short circuit protection | ||||||
Voltage Withstand | 1500VAC (Primary-secondary), 1500VAC (Primary-PE), 500VAC (Secondary-PE) | ||||||
Insulation Resistance | >5MΩ at 500VDC (between all I/O points and ground) | ||||||
Noise Immunity | ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog & Communication I/O: 1kV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m |
||||||
Grounding | The diameter of grounding wire shall not be less than that of L, N terminal of the power supply. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) |
||||||
Environment | Operation: 0°C~55°C (temperature), 5~95% (humidity), pollution degree 2 Storage: -25°C~70°C (temperature), 5~95% (humidity) |
||||||
Approvals | UL508, European community EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC | ||||||
Vibration/Shock Immunity | International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea) | ||||||
Weight | See below “Selection Table” | ||||||
Note: *1. It is suggested that the power output should not be supplied to HMIs. |
2 in stock
Delta: Analog Input Module (DVP04AD-S)
The A/D Conversion – In industrial automation, many measuring units are transmitted by analog signals. The most frequently adopted range for the signals are voltage -10 ~ 10V and current -20 ~ 20mA. To use the analog signals as the parameters for PLC operations, you have to convert them into digital values first. For example, the voltage -10 ~ 10V is first converted into values -8,000 ~ 8,000 by an A/D module, and the PLC will read/write the control registers (CR) in the AD module by FROM/TO instructions. The signals sent back to the PLC for operations will be digital K-8,000 ~ K8,000.
DVP04AD (or DVP06AD) analog signal input module receives external 4 (or 6) points of analog input signals (voltage or current) and converts them into 14-bit digital signals. The MPU can read/write the data in the module by using FROM/TO instructions in the program. There are 49 16-bit control registers in the module. You can select voltage input or current input by the wiring. Range for voltage input: ±10V (±8,000, resolution: 1.25mV). Range for current input: ±20mA (±4,000, resolution: 5μA).
2 in stock
PLC DVP12SE11
- No of Inputs: 14 Digits
- Power: 24 V DC
- PLC Brand :Delta
- Minimum Order: Quantity 1 Piece
Out of stock
Specifications for this Product:
Attribute | Value |
Manufacturer | Delta Electronics |
PLC Model | DVP16SP11T |
Product Series | DVP Series |
I/O points | 16 |
Digital Input | 8 |
Digital Output | 8 |
Voltage – Supply | 100 ~ 240VAC, 24V DC |
Output Type | Transistor |
DC Input | H type |
Mounting Type | Din Rail |
Termination Style | Pluggable Screw Terminal |
Maximum Operating Temperature | 55°C |
Minimum Operating Temperature | 0°C |
2 in stock
Brand: Delta
Model: DVP-04TC-S
Condition: New
2 in stock
SERIES | MELSEC-F SERIES |
---|---|
TYPE | FX3U |
INTERFACE | USB |
2 in stock
Type | FX3U |
---|---|
Power Supply (V) | 100-240 |
Current Type | AC |
Program Memory | 64K STEPS |
Program Memory Unit | RAM |
Integrated Digital Inputs | 16 |
Integrated Digital Outputs | 16 |
Output Type | TRANSISTOR |
Output Logic | SINK |
Local I/O Points | 256 |
Local Remote I/O Points | 384 |
Expandable | YES |
Cycle Time LD (ns) | 65 |
Cycle Time MOV (ns) | 642 |
RS-422 | 1 |
Power Consumption (W) | 35 |
Buffer Battery | YES |
Protection Class | IP10 |
Min. Ambient Temperature (°C) | 0 |
Max. Ambient Temperature (°C) | 55 |
Series | MELSEC-F SERIES |
Made in Japan