Delta
Showing all 5 results
-
Delta, PLC
Delta PLC ,DVP20SX211T
- Manufacturer: DELTA
- Product No. : DVP20SX211T
- Product type : DVP-SX2 2nd Generation Analog I/O Slim PLC
- PLC Model : DVP20SX211T
- Product Series: DVP Series
- Inputs+Outputs points / unit: 20 points
- Models: S-TYPE Main Processing Unit
- DC Input : H TYPE
- Transistor
- DVP-SX2 2nd Generation Analog I/O Slim PLC
- Shipping Weight : 1.5 Kg
SKU: n/a -
Delta, PLC
DVP-16SM11N | DELTA | I/O Extension Module DVP-16SM11N | DELTA | I/O Extension Module
- Manufacturer : DELTA
- Product No. : DVP-16SM11N
- Product type : I/O Extension Module
- Input type : DC Type (Sink or Source)
- Voltage/Input current : 24 V DC 5 mA
- Active level : Off – On: more than 16.5 V DC
- On – Off: less than 8 V DC
- Response time : Approx. 10ms
- Circuit isolation : By photocoupler
- Input display : LED
SKU: n/a -
Delta, PLC
DVP-16SP11T Delta PLC Extension module
Specifications for this Product:
Attribute Value Manufacturer Delta Electronics PLC Model DVP16SP11T Product Series DVP Series I/O points 16 Digital Input 8 Digital Output 8 Voltage – Supply 100 ~ 240VAC, 24V DC Output Type Transistor DC Input H type Mounting Type Din Rail Termination Style Pluggable Screw Terminal Maximum Operating Temperature 55°C Minimum Operating Temperature 0°C SKU: n/a -
Delta, PLC
DVP04AD-S,Delta Analog Output Module
Delta: Analog Input Module (DVP04AD-S)
The A/D Conversion – In industrial automation, many measuring units are transmitted by analog signals. The most frequently adopted range for the signals are voltage -10 ~ 10V and current -20 ~ 20mA. To use the analog signals as the parameters for PLC operations, you have to convert them into digital values first. For example, the voltage -10 ~ 10V is first converted into values -8,000 ~ +8,000 by an A/D module, and the PLC will read/write the control registers (CR) in the AD module by FROM/TO instructions. The signals sent back to the PLC for operations will be digital K-8,000 ~ K8,000.
DVP04AD (or DVP06AD) analog signal input module receives external 4 (or 6) points of analog input signals (voltage or current) and converts them into 14-bit digital signals. The MPU can read/write the data in the module by using FROM/TO instructions in the program. There are 49 16-bit control registers in the module. You can select voltage input or current input by the wiring. Range for voltage input: ±10V (±8,000, resolution: 1.25mV). Range for current input: ±20mA (±4,000, resolution: 5μA).
SKU: n/a