DVP40ES200R |DELTA| 100-240VAC 24DI 16DO Relay Output
DELTA PLC DVP40ES200R 100-240VAC 24DI 16DO Relay Output
Extended Product Type : DVP-ES2series
Product ID: DVP40ES200R
Delta Type Designation : DVP-ES2 series
- Size Guide
Size Guide
DRESSEST-SHIRTBOTTOMSDRESSESSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
T-SHIRTSize Chest Waist Hips 2XS 32 26 32 XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 All measurements are in INCHES
and may vary a half inch in either direction.
BOTTOMSSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
26,000.00৳ Original price was: 26,000.00৳ .21,000.00৳ Current price is: 21,000.00৳ .
Specification of Delta PLC DVP40ES200R
MPU points: 16 / 20 / 24 / 32 / 40 / 60
Program capacity: 16k steps
Built-in with 3 COM ports: 1 RS-232 port and 2 RS-485 ports, all are able to operate independently (Master/Slave)
Max. I/O points: 256 input points + 16 output points, or 256 output points + 16 input points
DVP-EX2 MPU is built in with 12-bit 4AD/2DA and offers analog/temperature modules of 14-bit resolution.
Built-in with 8 high-speed input points (2 points for 100kHz, 6 points for 10kHz) and supports U/D, U/D Dir, A/B counting modes
New motion control instructions: Close loop control, alignment mark, shield, immediate variable speed, S-Curve acceleration/deceleration
Application in emerging industry: Exclusive instructions and function blocks designed for PV solar tracker
Handy instructions for frequency inverter: For controlling the forward running, reverse running, RUN and STOP of Delta’s AC motor drives
Password protection: Password for subroutine, user ID, restriction on trial times
Highly efficient instruction efficient instruction execution
Power supply voltage : 100 ~ 240VAC (-15% ~ 10%); 50/60Hz + – 5%
Power consumption : 30VA
DC24V current output : 500mA
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- and can be installed easily. Users do not have to install any batteries in DVP-SE series PLCs. The PLC programs and the latched data are stored in the high-speed flash memories.
- D/A conversion and temperature measurement). 2 points of 100 kHz and 2 points of 10 kHz high-speed pulse output satisfy all kinds of applications. Small in size
- Encoder
- including digital I/O (max. 480 I/O points) and analog modules (for A/D
- No of Inputs 14 Digits Power 24 V DC PLC Brand Delta Minimum Order Quantity 1 Piece
- Pressure Sensor
- Pressure transmitter
- various instructions and with 16k steps program memory Connect to all DVP Slim type series extension modules and high-speed extension modules
Related Products
- Manufacturer : DELTA
- Product No. : DVP-16SM11N
- Product type : I/O Extension Module
- Input type : DC Type (Sink or Source)
- Voltage/Input current : 24 V DC 5 mA
- Active level : Off – On: more than 16.5 V DC
- On – Off: less than 8 V DC
- Response time : Approx. 10ms
- Circuit isolation : By photocoupler
- Input display : LED
3 in stock
SERIES | MELSEC IQ-F SERIES |
---|---|
TYPE | RELAY OUTPUT |
OCCUPIED I/O POINTS ON PLC | 16 |
INTEGRATED DIGITAL OUTPUTS | 16 |
OUTPUT TYPE | RELAY |
1 in stock
- Manufacturer : Mitsubishi Electric
- Product No. : FX2N-4AD
- Product type : Analog Input Modules
- Power Supply: 5 VDC/30 mA (from main unit); 24 VDC/55 mA
- Analog Channels: 4 inputs
- Analog Input Range: -10 to + 10 VDC / -20 to +20mA DC / 4 to 20 mA DC
- Resolution (voltage): 5mV (11 bit + sign)
- Related I/O points: 8
- Weight : 0.30 Kg
1 in stock
Specifications for this Product:
Attribute | Value |
Manufacturer | Delta Electronics |
PLC Model | DVP16SP11T |
Product Series | DVP Series |
I/O points | 16 |
Digital Input | 8 |
Digital Output | 8 |
Voltage – Supply | 100 ~ 240VAC, 24V DC |
Output Type | Transistor |
DC Input | H type |
Mounting Type | Din Rail |
Termination Style | Pluggable Screw Terminal |
Maximum Operating Temperature | 55°C |
Minimum Operating Temperature | 0°C |
2 in stock
- Manufacturer: DELTA
- Product No. : DVP20SX211T
- Product type : DVP-SX2 2nd Generation Analog I/O Slim PLC
- PLC Model : DVP20SX211T
- Product Series: DVP Series
- Inputs Outputs points / unit: 20 points
- Models: S-TYPE Main Processing Unit
- DC Input : H TYPE
- Transistor
- DVP-SX2 2nd Generation Analog I/O Slim PLC
- Shipping Weight : 1.5 Kg
Out of stock
Delta: Analog Input Module (DVP04AD-S)
The A/D Conversion – In industrial automation, many measuring units are transmitted by analog signals. The most frequently adopted range for the signals are voltage -10 ~ 10V and current -20 ~ 20mA. To use the analog signals as the parameters for PLC operations, you have to convert them into digital values first. For example, the voltage -10 ~ 10V is first converted into values -8,000 ~ 8,000 by an A/D module, and the PLC will read/write the control registers (CR) in the AD module by FROM/TO instructions. The signals sent back to the PLC for operations will be digital K-8,000 ~ K8,000.
DVP04AD (or DVP06AD) analog signal input module receives external 4 (or 6) points of analog input signals (voltage or current) and converts them into 14-bit digital signals. The MPU can read/write the data in the module by using FROM/TO instructions in the program. There are 49 16-bit control registers in the module. You can select voltage input or current input by the wiring. Range for voltage input: ±10V (±8,000, resolution: 1.25mV). Range for current input: ±20mA (±4,000, resolution: 5μA).
2 in stock
SERIES | MELSEC-F SERIES |
---|---|
TYPE | FX3U |
INTERFACE | USB |
2 in stock
Specifications
Attribute | Value |
For Use With | FX2N Series |
Manufacturer Series | FX2N |
Number of Inputs | 40 (Digital) |
Output Type | Relay |
Input Type | Digital |
Voltage Category | 100 → 240 V ac |
Number of Outputs | 40 (Relay) |
Communication Port Type | RS232, RS422, RS485 |
Program Capacity | 8000 Steps |
Programming Language Used | Ladder Logic |
Mounting Type | DIN Rail |
Programming Interface | Computer |
Length | 90mm |
Dimensions | 90 x 285 x 87 mm |
Battery Backup | Yes |
Depth | 87mm |
Number of Communication Ports | 1 |
Width | 285mm |
Minimum Operating Temperature | 0°C |
Maximum Operating Temperature | 55°C |
Output Current | 2 A |
- Made in JAPAN
1 in stock
Features
|
|
Brand Name : | Mitsubishi |
Type of Product : | PLC Main Units with 64 I/O |
No. of Inputs (Digital/Analog) : | 32 Input Points |
No. of Outputs (Digital/Analog) : | 32 Relay Output |
Output Type : | Relay |
Usage : | FX3U Series |
Made in JAPAN
1 in stock
Type | FX3U |
---|---|
Power Supply (V) | 100-240 |
Current Type | AC |
Program Memory | 64K STEPS |
Program Memory Unit | RAM |
Integrated Digital Inputs | 16 |
Integrated Digital Outputs | 16 |
Output Type | TRANSISTOR |
Output Logic | SINK |
Local I/O Points | 256 |
Local Remote I/O Points | 384 |
Expandable | YES |
Cycle Time LD (ns) | 65 |
Cycle Time MOV (ns) | 642 |
RS-422 | 1 |
Power Consumption (W) | 35 |
Buffer Battery | YES |
Protection Class | IP10 |
Min. Ambient Temperature (°C) | 0 |
Max. Ambient Temperature (°C) | 55 |
Series | MELSEC-F SERIES |
Made in Japan
2 in stock
Brand: Delta
Model: DVP-04TC-S
Condition: New
2 in stock
Reviews
There are no reviews yet.