Mitsubishi PLC FX3U-64MR/ES-A Programmable Logic Controller FX3U64MR/ES-A
Features
|
|
Brand Name : | Mitsubishi |
Type of Product : | PLC Main Units with 64 I/O |
No. of Inputs (Digital/Analog) : | 32 Input Points |
No. of Outputs (Digital/Analog) : | 32 Relay Output |
Output Type : | Relay |
Usage : | FX3U Series |
Made in JAPAN
- Size Guide
Size Guide
DRESSEST-SHIRTBOTTOMSDRESSESSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
T-SHIRTSize Chest Waist Hips 2XS 32 26 32 XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 All measurements are in INCHES
and may vary a half inch in either direction.
BOTTOMSSize Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
31,000.00৳ Original price was: 31,000.00৳ .29,000.00৳ Current price is: 29,000.00৳ .
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- and can be installed easily. Users do not have to install any batteries in DVP-SE series PLCs. The PLC programs and the latched data are stored in the high-speed flash memories.
- D/A conversion and temperature measurement). 2 points of 100 kHz and 2 points of 10 kHz high-speed pulse output satisfy all kinds of applications. Small in size
- Encoder
- including digital I/O (max. 480 I/O points) and analog modules (for A/D
- No of Inputs 14 Digits Power 24 V DC PLC Brand Delta Minimum Order Quantity 1 Piece
- Pressure Sensor
- Pressure transmitter
- various instructions and with 16k steps program memory Connect to all DVP Slim type series extension modules and high-speed extension modules
Related Products
DVP10SX11T
DVP S-Series Analogue CPU
Input: 6 Sink/Source 24VDC
Output: 2 NPN Transistor
Analog In: 2 points (-20>20mA _ -10> 10V)
Analog Out: 2 points (-20>20mA _ -10> 10V)
COM: 2 RS232/RS485 ports
Delta’s high-performance, high-speed DVP series PLCs are the most efficient and incorporate communication capabilities. Benefits include numerous convenient built-in controls for easy access to operations and monitoring of communication functions. The module-type unit offers huge space savings, allowing easy clip-on expansion possibilities. The high performance and large I/O units of the PLCs are a high value solution for machine control and industrial automation.
Common features
Adopts 32-bit CPU
Clip-on extension modules – general (right side)
Plug-in terminals for easy wiring and maintenance
Compact size (H) 90 mm x (D) 60 mm DIN rail mounting
Built-in high-speed counters up to 100-200 kHz (depending on model)
Dual RS232 and RS485 MODBUS ASCII / RTU compatible communication ports
Program language: instruction list (IL), ladder diagram (LD), sequential function diagram (SFC)
SX2 series digital and analogue I/Os
The slim-type SX2-series PLC offers 6/14 digital and 12-bit analogue I/O points built-in. It is extendable with the DVP-S series left- and right-side extension modules.
Key features:
No battery required
Execution speed: LD: 0.35 ?s
Supports 2-axis linear and arc interpolation
High speed counters: 2 x 100kHz and 6 x 10kHz
High speed pulse output: 2 x 100kHz and 2 x 10kHz
Program capacity: 16k steps / data log: 10k words
Supports DVP-S series left-side (high-speed) expansion modules
Supports standard MODBUS ASCII / RTU protocol and PLC connection function
1 in stock
- Manufacturer : Mitsubishi Electric
- Product No. : FX2N-16EX-ES/UL
- Product type : Input Module Extension Block
- Integrated Inputs : 16 (24 VDC)
- Integrated Inputs / Outputs : 16
- ON Voltage (Max.) : Relay version: < 240 VAC, < 30 VDC; Transistor version: 5 – 30 VDC; Triac version: 85 – 242 VAC
- Stocked Item : S
- 5VDC Current Consumption (mA) : 4
2 in stock
series MELSEC-F SERIES
Type FX3U
Power Supply (V) 24
Current Type DC
Occupied I/O Points on PLC 8
Integrated Analogue Outputs 4
Output Voltage Range (V) 0-10
Output Current Range (mA) 4-20
Min. Ambient Temperature (°C) 0
Max. Ambient Temperature (°C) 55
1 in stock
SERIES | MELSEC-F SERIES |
---|---|
TYPE | FX3U |
INTERFACE | USB |
2 in stock
SERIES | MELSEC-F SERIES |
---|---|
TYPE | FX2N |
OCCUPIED I/O POINTS ON PLC | 8 |
INTEGRATED DIGITAL INPUTS | 8 |
Made in JAPAN
4 in stock
- Manufacturer : Mitsubishi Electric
- Product No. : FX2N-4AD
- Product type : Analog Input Modules
- Power Supply: 5 VDC/30 mA (from main unit); 24 VDC/55 mA
- Analog Channels: 4 inputs
- Analog Input Range: -10 to + 10 VDC / -20 to +20mA DC / 4 to 20 mA DC
- Resolution (voltage): 5mV (11 bit + sign)
- Related I/O points: 8
- Weight : 0.30 Kg
1 in stock
SERIES | MELSEC IQ-F SERIES |
---|---|
TYPE | RELAY OUTPUT |
OCCUPIED I/O POINTS ON PLC | 16 |
INTEGRATED DIGITAL OUTPUTS | 16 |
OUTPUT TYPE | RELAY |
1 in stock
Specifications
Attribute | Value |
For Use With | FX2N Series |
Manufacturer Series | FX2N |
Number of Inputs | 40 (Digital) |
Output Type | Relay |
Input Type | Digital |
Voltage Category | 100 → 240 V ac |
Number of Outputs | 40 (Relay) |
Communication Port Type | RS232, RS422, RS485 |
Program Capacity | 8000 Steps |
Programming Language Used | Ladder Logic |
Mounting Type | DIN Rail |
Programming Interface | Computer |
Length | 90mm |
Dimensions | 90 x 285 x 87 mm |
Battery Backup | Yes |
Depth | 87mm |
Number of Communication Ports | 1 |
Width | 285mm |
Minimum Operating Temperature | 0°C |
Maximum Operating Temperature | 55°C |
Output Current | 2 A |
- Made in JAPAN
1 in stock
PLC DVP12SE11
- No of Inputs: 14 Digits
- Power: 24 V DC
- PLC Brand :Delta
- Minimum Order: Quantity 1 Piece
Out of stock
Brand: Delta
Model: DVP-04TC-S
Condition: New
2 in stock
Analog I/O Module
● 4 points of analog input voltage (-10 V ~ +10 V) / current (-20 mA ~ +20 mA)
● 2 points of analog output voltage (0 V ~ +10 V) / current (0 mA ~ +20 mA)
● Input / output resolution: 12-bit
● Built-in RS-485 interface
● Single-ended input
Product category
PLC
sub-category
DVP Slim Series
Partner name
Delta
Series name
DVP-Slim Expansion
Attributes
PLC Module
Expansion Module
I/O Selection
Mix AI/AO
Supply
24VDC
Output Type
N.A.
In Built
1 in stock
odel | ATO-DVP-ES2 | ||||||
Builit-in I/O | 16 / 20 / 24 / 32 / 40 / 60 I/O points | ||||||
Power Supply | 100 ~ 240V AC (-15% ~ +10%), 50/60Hz ±5% | ||||||
Connector | European standard removable terminal block (Pin pitch: 5mm) | ||||||
Operation | ATO-DVP-ES2 PLC starts to run when the power rises to 95~100V AC and stops when the power drops to 70V AC. If the power is suddenly cut off, the PLC will continue running for 10ms. |
||||||
Power Supply Fuse | 2A / 250V AC | ||||||
Power Consumption | 30VA | ||||||
DC 24V Current Output *1 | 500mA | ||||||
Power Supply Protection | DC 24V output short circuit protection | ||||||
Voltage Withstand | 1500VAC (Primary-secondary), 1500VAC (Primary-PE), 500VAC (Secondary-PE) | ||||||
Insulation Resistance | >5MΩ at 500VDC (between all I/O points and ground) | ||||||
Noise Immunity | ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog & Communication I/O: 1kV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m |
||||||
Grounding | The diameter of grounding wire shall not be less than that of L, N terminal of the power supply. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) |
||||||
Environment | Operation: 0°C~55°C (temperature), 5~95% (humidity), pollution degree 2 Storage: -25°C~70°C (temperature), 5~95% (humidity) |
||||||
Approvals | UL508, European community EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC | ||||||
Vibration/Shock Immunity | International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea) | ||||||
Weight | See below “Selection Table” | ||||||
Note: *1. It is suggested that the power output should not be supplied to HMIs. |
2 in stock